Flow Controller for General Liquid

Inquire now

Flow Controller for General Liquid

Click to enlarge image

 Origin Korea
 Model Number FC410C

Feature

  • Gross and net total/ gross or net accumulated total/ gross and net flow rate
  • 4-20mA and Pt 100 Ohms Temperature inputs
  • Gross or net scaled pulse output
  • 4-20mA Analog output
  • Alarm output

Over View

The FC410C Series flow controllers are designed to measure volumetric flow for liquids with temperature input. This corrected volume is at standard reference condition. This Series is ideally suited to custody transfer applications and includes the API/ASTM equations covering general petroleum products and LPG. The BC410C Series is direct RTD input or 4-20mA temperature input.

General

Display 7-digit 14.1mm(0.56Inch)7-segment LED
Display Update Rate 0.25-second
Decimal Points Fully programmable for Rate and Total
Time Base The Rate can be displayed in unit per second, per minute, per hour or per day
Data Retention Set up parameters and totals stored in non-volatile memory with 10 years retention
Operation Temperature 0°C to 55°C
Power AC 85-264V / DC 24V
Power Consumption 10VA
Transducer Supply 8V or 12V selectable, 50mA max

Flow Inputs

Frequency(Pulse) Input
Frequency Range 0 to 5 kHz
Signal Type sine wave, open collector, reed switch, proximity switch, voltage and current pulse
K-factor Range 0.0001 - 50000.0000(the pulse per units)
Analog Input
Inputs 4-20 mA or 1-5V option
Input Impedance Current 250 ohms
Voltage 10K ohms
Accuracy 0.05%
Span 0.0001 to 50000.0000
Zero 0.0000 to 50000.0000
Cut-off Point A low flow rate cut-off can be programmed below which flow is not registered. The cut-off is programmed as a percentage of span relationship Linear or square root or programmable open Channel For open channel flow meters; the power of The input relationship is programmable between 0 and 9.99.

Temperature Input

RTD Input
Type Platinum PT100(DIN)
Temperature Range -50(-58°F) to 50°C(122°F)(Refer to the ordering information for detail)
Accuracy 0.1°C
Linearity The non-linearity of the RTD is internally compensated for.
Analog Input(4-20 mA)
Inputs Impedance 250 ohms
Measurement Range -273°C(-459.4°F) to 1200°C(2192°F)
Accuracy 0.05%

Pulse Output

Function Open collector output with a pulse produced on each increment of the accumulated total(gross, net, mass or energy).
Pulse Width 10 ms(negative going pulse)
Duty Cycle 49 pulses/sec. Max.
Output Current sinking output transistor 50mA, 30vdc max.(Pulse output is suitable for driving remote counter or PLC's)

Relay Output

Function High and low, high-high and high or low and low-low flow rate alarms based on the flow rate in energy gross volume, net volume, mass or energy
Max. Switching Power 2000VA, 240W
Max. Switching Voltage AC250V, DC30V
Max. Switching Current 8 Amps

4-20mA Output

Function Outputs flow rate in gross volume, net volume, mass or energy, The 4 and 20 mA points can be programmed to provide a fully scaled output.
Resolution 12-bit
Accuracy Better than 0.025%
Maximum Load 500 ohms internally powered. 950 ohms from external 24V dc.
Isolation Output is isolated.

RS232/422/485

Type Both RS232 and RS422/485 are provided.(Note : When using the RS422/485, multi drop communication can be implemented with up to 32 instruments connected to a common bus.
Function Printer and computer protocols are fully programmable.
Printer A print is initiated on each reset or at a programmable time interval.
Computer An ASCII based protocol enable all display parameters to be read and the totals to be reset.
Baud Rate 1200 to 19200 BPS
Data Bit 8-bit
Parity Bit None
Data Logging Output generated at intervals of once a minute to once every 24 hours. The total can be programmed to reset on each print or at 24:00 hours
Time A real time clock is provided to give time and date on each output.

Error Output

Function The Error output is out of range, no flow or communication fail indicated
Output An open collector transistor will sink 50 mA max.

Enclosure

Basic Enclosure
Dimension 72mm (H) x 144mm (W) x 177mm (D)
Material Polycarbonate, Aluminum
Panel Cutting Size 67mm x 139mm(±0.2mm)
Weather Proof
Protection IP65(Nema 4X)
Material Aluminum
Outside Dimension 248mm (H) x 162mm (W) x 87mm (D)
Explosion proof
Outside Dimension 270mm(H) x 290mm(W) x 280(D)
Mounting Dimension 90mm(H) x 83mm(W) x M8 Bolt
Classification

Division 1, Class I Group-A, B,C,D
Class II Group-E, F&G
ClassIII
Zone 1 or 2, Exd II B T6

Standards and Approvals

CE
Manufactured under ISO 9001

Dimension

Ordering information

MODEL Order Code Description
FC410C-             Flow Controller with LCD Display(LED-Backlight)
Flow Senseor P
A
          Frequency Type Flow Meter Input
4-20mA Analog Type Flow Meter Input
Temperature   A
R
        4-20mA Analog Temperature Input
Pt 100 Ohms RTD Input(0~100°C)
In/Output     0
1
2
      Basic Mode(No Option)
4-20mA Analog Output
Remote Switch Input
Communication  

 

  0
1
2
    None Communication
RS-232 Communication
RS-422/RS-485 Communication
Power         A
D
  AC 85-264V(Free Voltage)
DC 24V
Case           0
1
2

Only Basic
With Weather Proof
With Explosion Proof