Origin |
Korea |
Model Number |
LIU100 |
Feature
- Stand-alone or System integrated Operation
- large Display(2.3" high)
- User Settable Decimal Point with Communication or Switch
- Watch dog timer checking function
- Serial Communication(RS 422 or RS 485) Support
- Pulse Signal Input
Over View
LIU 100 Series Indicator is able to easy read the data by the use of large-sized 7 Segment LED display.
The digit number is able to mount one place, so both the cost down and field state are able to easy observe.
LIU 100 is usable independently; also user is able to construction system with a high position computer and DCS.
DIigit
Able to use mixing diverse decimal point accordign as the field condition
Interface
Able to use only pulse input according as use condition, also this is possible receives the data from communication
Watch Dog Timer
If porgram breakdown, return to normalcy in 1-Sec.
Pulse Input
Increase in pulse number with scaled pulse input
Communication(RS-422/485)
Total and flow rate data communication Between LIU100 series and Flow controller Batch controller computer.
General
| Display |
7-segment LED : 2.3-inch high |
| Display Number |
1- Line : 11 or 12-digit |
| Display Update Rate |
0.25-second |
| Decimal Points |
Fully programmable with communication or switch |
| Operation Temperature |
0°C to 55°C -20°C to 55°C(option) |
| Power |
AC 85-264V(free voltage) 47Hz to 63Hz |
| Power Consumption |
30VA |
Pulse Inputs
| Frequency Range |
0 to 5 kHz |
| Signal Type |
Open collector or reed switch(relay contact) |
| K-factor |
Not support. 1-pulse is 1-Counter |
Temperature Input
| |
| RTD Input |
| Type |
Platinum PT100(DIN) |
| Temperature Range |
-50(-58°F) to 50°C(122°F)(Refer to the ordering information for detail) |
| Accuracy |
0.1°C |
| Linearity |
The non-linearity of the RTD is internally compensated for. |
Pulse Output
| Function |
Open collector output with a pulse produced on each increment of the accumulated total(gross, net, mass or energy). |
| Pulse Width |
10 ms(negative going pulse) |
| Duty Cycle |
49 pulses/sec. Max. |
| Output |
Current sinking output transistor 50mA, 30vdc max.(Pulse output is suitable for driving remote counter or PLC's) |
Circuit
Remote Switch input from floating contact
Note : Switches or relays must be floating(not connected to other circuit) and suitable for switching low voltage signal.
Serial Communications
Type
Both RS422 and RS485 are provided. Note : when using the RS422/485, multi drop communication can be implemented with up to 32 instruments connected to a common bus.
Baud rate
1200-BPS to 9600-BPS 8-bit/ none parity bit
Dimension
1-Line : 520(W) x 220(H) x 130(D) mm
|