| Products |
|
 |
Petro Loading Counter with Temperature Compensation |
|
|
|

|

|
Click to enlarge image
|
Origin |
Korea |
Model Number |
PLC600 |
Feature
- Gross, net, weight batch count / gross, net/ gross and net
- Temperature compensation to API Tables
- gross or net scaled pulse output
- Basic 1-channel(Option 2-Channel loading)
- Dual data communication port with protocol matching
- Fully isolated External Input and Output
Over View
The PCL600 Series batch controllers use temperature correction to calculate the volumetric flow for liquids at standard reference conditions. The PCL600 Series is ideally suited to custody transfer applications and includes the API/ASTM equations covering general petroleum products and LPG. The PCL600 Series is direct RTD input or 4-20mA temperature input.
General
| Display |
Main : Large 2-line x 20-character LCD With LED B/L Sub : Small 2-line x 20-character LCD With LED B/L |
| Display Update Rate |
0.25-second |
| Decimal Points |
Fully programmable for Rate and Total |
| Time Base |
The Rate can be displayed in unit per second, per minute, per hour or per day |
| Data Retention |
Set up parameters and totals stored in non-volatile memory with 10 years retention |
| Operation Temperature |
-25°C to 60°C |
| Power |
AC110V/ 220V Selectable(50/60Hz) |
| Transducer Supply |
12V or 24V selectable, 100mA max |
Flow Inputs
| Frequency(Pulse) Input |
| Number Of channel |
2-Channel |
| Frequency Range |
0.5 to 10 kHz Max |
| Signal Type |
open collector, reed switch, voltage and current pulse |
| K-factor Range |
0.0001 - 50000.0000(the pulse per units) |
| Analog Input |
| Number Of channel |
2-Channel |
| Inputs |
4-20 mA or 1-5V option |
| Input Impedance |
Current 250 ohms Voltage 10K ohms |
| Accuracy |
0.05% |
| Span |
0.0001 to 50000.0000 |
| Zero |
0.0000 to 50000.0000 |
| Cut-off Point |
A low flow rate cut-off can be programmed below which flow is not registered. The cut-off is programmed as a percentage of span relationship Linear or square root. |
Temperature Input
| RTD Input |
| Number Of channel |
2-Channel |
| Type |
Platinum PT100(DIN) |
| Temperature Range |
-100°C to +200°C(Refer to the ordering information for detail) |
| Accuracy |
0.1°C |
| Linearity |
The non-linearity of the RTD is internally compensated for. |
| Analog Input |
| Number Of channel |
2-Channel |
| Inputs Impedance |
250 ohms |
| Measurement Range |
-100°C to +200°C |
| Accuracy |
0.05% |
Digital Input
| Channel |
6-Channel |
| Function |
Open collector Input For External switch, Earth Device, Aux pulse input. etc |
| Pulse Width |
10 ms(negative going pulse) |
| Nominal Input Voltage |
12VDC |
| Maximum Input Voltage |
12VDC |
Valve Control Output
| Function |
Two stage valve control Digital valve control |
| Relay Type |
AC Solid-State-Relay or Mechanical Contact-Relay |
| Load Voltage |
90-240VAC or 250VAC/30VDC |
| Max. Current |
1.5 Amps or 10A |
4-20mA Output
| Channel |
2-Channel |
| Function |
Outputs flow rate in gross volume, net volume, mass or energy, The 4 and 20 mA points can be programmed to provide a fully scaled output. |
| Resolution |
12-bit |
| Accuracy |
Better than 0.025% |
| Maximum Load |
500 ohms internally powered. 950 ohms from external 24V dc. |
| Isolation |
Output is isolated. |
RS232/422/485
| Type |
Both RS232 and RS422/485 are provided.(Note : When using the RS422/485, multi drop communication can be implemented with up to 32 instruments connected to a common bus. |
| Communication Channel |
2-Channel |
| Isolation |
Communication is optical isolation |
| Function |
Printer and computer protocols are fully programmable. |
| Printer |
A print is initiated on each reset or at a programmable time interval. |
| Computer |
An ASCII based protocol enable all display parameters to be read and the totals to be reset. |
| Baud Rate |
1200 to 19200 BPS |
| Data Bit |
8-bit |
| Parity Bit |
None |
| Time |
A real time clock is provided to give time and date on each output. |
Digital Output
| Function |
Open collector output with a pulse produced on each increment of the accumulated total(gross, net, mass or energy). |
| Pulse Width |
10ms(negative going pulse) |
| Duty Cycle |
49 pulses/sec. Max. |
| Channel |
5-Channel |
| Output |
Current sinking output transistor 50ma, 30vdc max.(Pulse output is suitable for driving remote counter or PLC's) |
Enclosure
| Explosion proof |
| Outside Dimension |
270mm(H) x 290mm(W) x 280(D) Notice : H is not fixed |
| Mounting Dimension |
90mm(H) x 83mm(W) x M8 Bolt |
| Classification |
Division 1, Class I Group-A, B,C,D Class II Group-E, F&G ClassIII Zone 1 or 2, Exd II B T6
|
Application
- Truck Loading
- Railcar Loading
- Chemical Loading
- LPG, Lube Oils
- Barge Loading
- Shipping Docks
- Bulk plants
System
Modeling
| MODEL |
Description |
| PCL600- |
|
|
|
|
|
Petro loading Controller |
| Temperature |
N A R |
|
|
|
|
No Option 4-20mA Analog Temperature Input Pt 100 Ohms RTD Input |
| Channel |
|
1 2
|
|
|
|
One arm loading(STD) Two arm loading(OPTION) |
| Analog Output |
|
|
0 1 2 |
|
|
No option 4-20mA output 1 channel 4-20mA output 2 channel |
| Case |
|
|
|
E |
X |
Explosion proof
|
Dimension
|
|
|
|
| |
|
|
|